    <title>topic Re: All wires are connected but furnace won't turn on. in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469701#M101513</link>
    <description>&lt;P&gt;I have the Nest wired like this&lt;/P&gt;&lt;P&gt;Y1- cool (blue in my system),&amp;nbsp;G-green (fan),&amp;nbsp;W1-white (heat), RH-red (power)&lt;/P&gt;&lt;P&gt;RC &amp;amp; C are connected to get power from the 24v (two wire charger, plugged into the wall)&lt;/P&gt;&lt;DIV class=""&gt;&amp;nbsp;&lt;/DIV&gt;</description>
    <pubDate>Tue, 15 Aug 2023 19:44:22 GMT</pubDate>
    <dc:creator>ChrisVan</dc:creator>
    <dc:date>2023-08-15T19:44:22Z</dc:date>
    <item>
      <title>All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469434#M101439</link>
      <description>&lt;P&gt;Hello,&amp;nbsp; I have a gas furnace with ac.&amp;nbsp; I ran a plug in 2 wire 24v plug for the C wire power.&amp;nbsp;&lt;/P&gt;&lt;P&gt;The learning nest shows all the wires are connected and there aren't any error messages.&amp;nbsp; But during the test mode it won't turn on the furnace can at all.&amp;nbsp;&lt;/P&gt;&lt;P&gt;I can't connect with my phone as well.&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="20230813_165631.jpg" style="width: 4000px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/28005i2A77D757D945BE09/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="20230813_165631.jpg" alt="20230813_165631.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt; This was the old thermostat.&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="20230813_164352.jpg" style="width: 4000px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/28006i056E98565E5ECC99/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="20230813_164352.jpg" alt="20230813_164352.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt; This is inside the furnace.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 15 Aug 2023 10:30:23 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469434#M101439</guid>
      <dc:creator>ChrisVan</dc:creator>
      <dc:date>2023-08-15T10:30:23Z</dc:date>
    </item>
    <item>
      <title>Re: All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469570#M101462</link>
      <description>&lt;P&gt;Red wire should connect to nest Rh slot. Also don’t see the C connected at your furnace. Do you have a 5th wire that you can use? Good luck.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 15 Aug 2023 16:37:32 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469570#M101462</guid>
      <dc:creator>HVAC</dc:creator>
      <dc:date>2023-08-15T16:37:32Z</dc:date>
    </item>
    <item>
      <title>Re: All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469701#M101513</link>
      <description>&lt;P&gt;I have the Nest wired like this&lt;/P&gt;&lt;P&gt;Y1- cool (blue in my system),&amp;nbsp;G-green (fan),&amp;nbsp;W1-white (heat), RH-red (power)&lt;/P&gt;&lt;P&gt;RC &amp;amp; C are connected to get power from the 24v (two wire charger, plugged into the wall)&lt;/P&gt;&lt;DIV class=""&gt;&amp;nbsp;&lt;/DIV&gt;</description>
      <pubDate>Tue, 15 Aug 2023 19:44:22 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469701#M101513</guid>
      <dc:creator>ChrisVan</dc:creator>
      <dc:date>2023-08-15T19:44:22Z</dc:date>
    </item>
    <item>
      <title>Re: All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469704#M101514</link>
      <description>&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Nest image.jpg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/28023iFB692C7EF4DD0094/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Nest image.jpg" alt="Nest image.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Tue, 15 Aug 2023 19:45:16 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469704#M101514</guid>
      <dc:creator>ChrisVan</dc:creator>
      <dc:date>2023-08-15T19:45:16Z</dc:date>
    </item>
    <item>
      <title>Re: All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469726#M101530</link>
      <description>&lt;P&gt;24 volt needs to be from furnace not external transformer. You already have the red wire connected from furnace to nest slot Rh just need another wire to go from furnace C / common to C on nest. If you can’t pull a wire or don’t have extra wire You can &amp;nbsp;use the green wire to go to C on nest but you need to swap at furnace also put green G wire to C also need to put small wire jumper at furnace between G &amp;amp; Y on the furnace where the blue wire is connected. &amp;nbsp; if you use green wire you lose ability to turn on fan only by itself but fan would come on with AC because of the jumper in between Y &amp;amp; G. Always Turn off power to furnace before working on it. Hope that helps. Good luck.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 15 Aug 2023 20:05:52 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/469726#M101530</guid>
      <dc:creator>HVAC</dc:creator>
      <dc:date>2023-08-15T20:05:52Z</dc:date>
    </item>
    <item>
      <title>Re: All wires are connected but furnace won't turn on.</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/470962#M101796</link>
      <description>&lt;P&gt;Hi folks,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/404153"&gt;@ChrisVan&lt;/a&gt;&lt;/SPAN&gt;, thanks for reaching out to us, and I'm sorry to hear about the situation. Please answer the following:&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;UL&gt;
 &lt;LI&gt;Does the thermostat screen indicate that it’s actively calling for heating?&lt;/LI&gt;
 &lt;LI&gt;When did heating last work?&lt;/LI&gt;
 &lt;LI&gt;Did you select the correct fuel type?&lt;/LI&gt;
 &lt;LI&gt;Do the LED lights blink on the HVAC control board?&lt;/LI&gt;
 &lt;LI&gt;When was the last time you changed the furnace's air filter?&lt;/LI&gt;
 &lt;LI&gt;Have you experienced extremely cold weather lately?&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Also, please gather the power readings of your thermostat on its &lt;STRONG&gt;Settings &amp;gt; Technical Info &amp;gt; Power&lt;/STRONG&gt; (Battery, VOC, VIN, and lIN).&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I appreciate your help,&amp;nbsp;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/400896"&gt;@HVAC&lt;/a&gt;.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Best,&lt;/P&gt;
&lt;P&gt;Zoe&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Fri, 18 Aug 2023 21:22:46 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/All-wires-are-connected-but-furnace-won-t-turn-on/m-p/470962#M101796</guid>
      <dc:creator>zoeuvre</dc:creator>
      <dc:date>2023-08-18T21:22:46Z</dc:date>
    </item>
  </channel>
</rss>
