    <description>&lt;P&gt;Well I am totally confused!&lt;/P&gt;&lt;P&gt;You say &lt;STRONG&gt;''Everything appears to be working just fine apart from it seems the heating pump runs continuously 24/7'&lt;/STRONG&gt;' Now you are saying &lt;STRONG&gt;'' the boiler does not fire up, when the nest reaches temp the boiler isnt firing'&lt;/STRONG&gt;', so which part is working just fine?&lt;/P&gt;&lt;P&gt;That means to me nothing is working correctly!&lt;/P&gt;&lt;P&gt;What system do you have and did you follow the installation wiring diagram for your system?&lt;/P&gt;</description>
    <pubDate>Tue, 12 Dec 2023 16:04:18 GMT</pubDate>
    <dc:creator>Frustratedddd</dc:creator>
    <dc:date>2023-12-12T16:04:18Z</dc:date>
    <item>
      <title>Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/559750#M111854</link>
      <description>&lt;P&gt;Hello,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I have just had installed a Nest 3rd Gen thermostat so I can control my heat remotely, on my 12 year old Worcester Bosch 40CDi Combi Boiler.&lt;/P&gt;&lt;P&gt;Everything appears to be working just fine apart from it seems the heating pump runs continuously 24/7. &amp;nbsp;Im pretty sure this should not happen, so wondering if anyone can shed some light on how I fix this issue as my friend who installed it is also unsure how to fix this.&amp;nbsp;&lt;/P&gt;&lt;P&gt;many thanks for any advice in advance.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Neil&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 03:59:12 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/559750#M111854</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-12T03:59:12Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560104#M111882</link>
      <description>&lt;P&gt;That sounds like a bit of an issue, as the thermostat is the part that turns the pump on/off! Certainly should not run 24hr, that defeats the object of having a thermostat. That means it's not wired correctly by the sounds of things.&lt;/P&gt;&lt;P&gt;For it to run 24hr means you have no switching, and would assume the installer has connected live neutral direct to the pump!!&lt;/P&gt;&lt;P&gt;What happens when you turn the stat from calling for heat and not calling? The pump still runs?&lt;/P&gt;&lt;P&gt;Can you upload a picture of the Heat Link wiring, and perhaps we can go from there.&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 13:41:30 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560104#M111882</guid>
      <dc:creator>Frustratedddd</dc:creator>
      <dc:date>2023-12-12T13:41:30Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560164#M111894</link>
      <description>&lt;P&gt;Hello. I will indeed get some photos of the wiring to post tomorrow. But just so you know the boiler does not fire up, when the nest reaches temp the boiler isnt firing, its just the pump stays on 24/7. The boiler will only fire when we need heat.&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 14:42:48 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560164#M111894</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-12T14:42:48Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560197#M111902</link>
      <description>&lt;P&gt;Well I am totally confused!&lt;/P&gt;&lt;P&gt;You say &lt;STRONG&gt;''Everything appears to be working just fine apart from it seems the heating pump runs continuously 24/7'&lt;/STRONG&gt;' Now you are saying &lt;STRONG&gt;'' the boiler does not fire up, when the nest reaches temp the boiler isnt firing'&lt;/STRONG&gt;', so which part is working just fine?&lt;/P&gt;&lt;P&gt;That means to me nothing is working correctly!&lt;/P&gt;&lt;P&gt;What system do you have and did you follow the installation wiring diagram for your system?&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 16:04:18 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560197#M111902</guid>
      <dc:creator>Frustratedddd</dc:creator>
      <dc:date>2023-12-12T16:04:18Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560223#M111909</link>
      <description>&lt;P&gt;Hi there &lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/478658"&gt;@neilfearnley&lt;/a&gt;&lt;/SPAN&gt; and thanks for reaching our Community. I'm sorry to hear about this, but I'll do my best to help you out. It's best to start from a picture of the wiring done on the Heat Link, as &lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/17110"&gt;@Frustratedddd&lt;/a&gt;&lt;/SPAN&gt; suggested.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 16:33:45 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560223#M111909</guid>
      <dc:creator>TudorL</dc:creator>
      <dc:date>2023-12-12T16:33:45Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560238#M111915</link>
      <description>&lt;P&gt;Hello. It was done by a local plumber, but he wasnt seemingly too good with Nest. prior to this I had a Worcester digital room stat on my wall, connected to the boiler. Timer functions were all handles by a TP200 unit that plugs into the front of the boiler. I had absolutely no issues with it, apart from I was not able to connect remotely and turn heating on/off while out of the home. The only thing that has changed is the installation of the Nest 3rd Gen, so I think I am fair to assume something is wrong there. Ill get some pictures of wiring soon as I am back near the boiler.&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 16:53:12 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560238#M111915</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-12T16:53:12Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560239#M111916</link>
      <description>&lt;P&gt;I will get some pictures soon as I am back near the boiler. Many thanks&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 16:53:45 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560239#M111916</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-12T16:53:45Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560255#M111919</link>
      <description>&lt;P&gt;No worries, keep us posted.&lt;/P&gt;</description>
      <pubDate>Tue, 12 Dec 2023 17:14:02 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/560255#M111919</guid>
      <dc:creator>TudorL</dc:creator>
      <dc:date>2023-12-12T17:14:02Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561150#M111982</link>
      <description>&lt;P&gt;Good morning all,&lt;/P&gt;&lt;P&gt;please see pictures of the wiring on &lt;A href="https://www.dropbox.com/scl/fo/zyot0apssrn22gip76niv/h?rlkey=l9ycp64qixkhjkxyfntvrfhr2&amp;amp;dl=0" target="_self"&gt;this&lt;/A&gt; link:-&lt;/P&gt;&lt;P&gt;&lt;A href="https://www.dropbox.com/scl/fo/zyot0apssrn22gip76niv/h?rlkey=l9ycp64qixkhjkxyfntvrfhr2&amp;amp;dl=0" target="_blank"&gt;https://www.dropbox.com/scl/fo/zyot0apssrn22gip76niv/h?rlkey=l9ycp64qixkhjkxyfntvrfhr2&amp;amp;dl=0&lt;/A&gt;&lt;/P&gt;&lt;P&gt;Hope this will help&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Neil&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 11:35:53 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561150#M111982</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T11:35:53Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561151#M111983</link>
      <description>&lt;P&gt;Wiring pics:-&lt;/P&gt;&lt;P&gt;&lt;A href="https://www.dropbox.com/scl/fo/zyot0apssrn22gip76niv/h?rlkey=l9ycp64qixkhjkxyfntvrfhr2&amp;amp;dl=0" target="_blank"&gt;https://www.dropbox.com/scl/fo/zyot0apssrn22gip76niv/h?rlkey=l9ycp64qixkhjkxyfntvrfhr2&amp;amp;dl=0&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 11:36:29 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561151#M111983</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T11:36:29Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561248#M111992</link>
      <description>&lt;P&gt;Thank you for the pictures. Just to confirm, as the wires are very long and only 2 colours, you have 2 wires in T1/T2 that go from there to the thermostat display, 2 wires in N/L that are neutral and high voltage live wire and 2 wires in terminals 2 and 3. The one in terminal 2 being high voltage (or low voltage wire if you have a low voltage/dry contact boiler) and the call for heat wire in terminal 3, correct?&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 12:26:06 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561248#M111992</guid>
      <dc:creator>AlexD</dc:creator>
      <dc:date>2023-12-13T12:26:06Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561254#M111993</link>
      <description>&lt;P&gt;That is correct yes&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 12:33:58 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561254#M111993</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T12:33:58Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561274#M111996</link>
      <description>&lt;P&gt;Apparently it may not be the pump thats running. my guy says its coming from the top of the boiler, behind the units in the &lt;A href="https://www.dropbox.com/scl/fi/t2c8bn323wn2y7wkba50f/image0.jpeg?rlkey=fyk50vdmvh46erhy108r4t8du&amp;amp;dl=0" target="_self"&gt;picture&lt;/A&gt;? Any help?&lt;/P&gt;&lt;P&gt;&lt;A href="https://www.dropbox.com/scl/fi/t2c8bn323wn2y7wkba50f/image0.jpeg?rlkey=fyk50vdmvh46erhy108r4t8du&amp;amp;dl=0" target="_blank"&gt;https://www.dropbox.com/scl/fi/t2c8bn323wn2y7wkba50f/image0.jpeg?rlkey=fyk50vdmvh46erhy108r4t8du&amp;amp;dl=0&lt;/A&gt;&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 13:01:23 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561274#M111996</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T13:01:23Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561312#M111999</link>
      <description>&lt;P&gt;Does terminal ''3'' at the Heat Link go to terminal Lr at the boiler?&lt;/P&gt;&lt;P&gt;Are Terminals ''Live &amp;amp; Terminal 2'' both just Live, coming from the boiler?&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 13:48:48 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561312#M111999</guid>
      <dc:creator>Frustratedddd</dc:creator>
      <dc:date>2023-12-13T13:48:48Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561320#M112000</link>
      <description>&lt;P&gt;Hello, from my sparky:-&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Terminal 3 (n/o) does go to Le at the boiler. Terminal 2 (com) is perm feed but from Ls at the boiler&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 14:07:29 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561320#M112000</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T14:07:29Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561321#M112001</link>
      <description>&lt;P&gt;Its looking like its not the heating pump running. Is there a fan at the top of the boiler, it could be this that is permanently running. I just assumed was the heating pump but appears not to be the case. The unit running is at the very top of the boiler.&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 14:08:48 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561321#M112001</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T14:08:48Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561393#M112015</link>
      <description>&lt;P&gt;Where is Le and what does that do?&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 17:21:15 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561393#M112015</guid>
      <dc:creator>Frustratedddd</dc:creator>
      <dc:date>2023-12-13T17:21:15Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561452#M112030</link>
      <description>&lt;P&gt;From Sparky….&lt;/P&gt;&lt;P&gt;Le??? I don't think there is an Le.&lt;BR /&gt;Boiler controls are as follows:&lt;BR /&gt;NS - neutral supply&lt;BR /&gt;LS - live supply&lt;BR /&gt;LR - live return (no/nc).&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 18:44:57 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561452#M112030</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T18:44:57Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561456#M112032</link>
      <description>&lt;P&gt;You wrote it!&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;Terminal 3 (n/o) does go to &lt;STRONG&gt;Le&lt;/STRONG&gt; at the boiler. Terminal 2 (com) is perm feed but from Ls at the boiler&lt;/SPAN&gt;&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 18:53:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561456#M112032</guid>
      <dc:creator>Frustratedddd</dc:creator>
      <dc:date>2023-12-13T18:53:26Z</dc:date>
    </item>
    <item>
      <title>Re: Neat 3rd Gen and Worcester Greenstar 40CDi</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561460#M112034</link>
      <description>&lt;P&gt;Let me get sparkys reply &lt;span class="lia-unicode-emoji" title=":see_no_evil_monkey:"&gt;🙈&lt;/span&gt; sorry. Give me 10&lt;/P&gt;</description>
      <pubDate>Wed, 13 Dec 2023 19:01:55 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Neat-3rd-Gen-and-Worcester-Greenstar-40CDi/m-p/561460#M112034</guid>
      <dc:creator>neilfearnley</dc:creator>
      <dc:date>2023-12-13T19:01:55Z</dc:date>
    </item>