<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622530#M120312</link>
    <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/552783"&gt;@N9&lt;/a&gt;&amp;nbsp;, can you upload the photo you took of the old thermostat before you removed the wires? &amp;nbsp;From what you are saying you have a Heat Pump system with Auxiliary Heat Strips.&amp;nbsp;&lt;BR /&gt;I need to see the photo of the old thermostat.&amp;nbsp;&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;AC Cooling Wizard&lt;/P&gt;</description>
    <pubDate>Fri, 24 May 2024 18:53:06 GMT</pubDate>
    <dc:creator>CoolingWizard</dc:creator>
    <dc:date>2024-05-24T18:53:06Z</dc:date>
    <item>
      <title>Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622524#M120308</link>
      <description>&lt;P&gt;BLUF: My Nest thinks my equipment is dual fuel when it's all electric single stage with aux heat coils.&lt;/P&gt;&lt;P&gt;How do I change these settings? Is this a result of the wiring?&lt;/P&gt;&lt;P&gt;I bought a Nest Gen 3 and jumped through some hoops to get it to install properly but it is up and running in cooling mode.&lt;/P&gt;&lt;P&gt;It replaced a Trane XL824. The XL824 has no backup battery capability so I would sometimes come home to find that because of a momentary power fluctuation my system would be completely off and would need to be reset at the breaker.&lt;/P&gt;&lt;P&gt;The Trane TAM7 air handler is on a single stage compressor for air and heat, but does have an aux heat coil set.&lt;/P&gt;&lt;P&gt;So I have a Y1 and a W1 and W2. The W2 being the aux heat I imagine.&lt;/P&gt;&lt;P&gt;Also I have a BK wire that on the advice of a different forum member I have connected to the * wiring input to be used to control humidity fan settings. But I don't know where to configure that in the Nest menus.&lt;/P&gt;&lt;P&gt;Any help would be appreciated.&lt;/P&gt;&lt;P&gt;Thanks,&lt;/P&gt;</description>
      <pubDate>Fri, 24 May 2024 18:43:25 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622524#M120308</guid>
      <dc:creator>N9</dc:creator>
      <dc:date>2024-05-24T18:43:25Z</dc:date>
    </item>
    <item>
      <title>Re: Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622530#M120312</link>
      <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/552783"&gt;@N9&lt;/a&gt;&amp;nbsp;, can you upload the photo you took of the old thermostat before you removed the wires? &amp;nbsp;From what you are saying you have a Heat Pump system with Auxiliary Heat Strips.&amp;nbsp;&lt;BR /&gt;I need to see the photo of the old thermostat.&amp;nbsp;&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;AC Cooling Wizard&lt;/P&gt;</description>
      <pubDate>Fri, 24 May 2024 18:53:06 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622530#M120312</guid>
      <dc:creator>CoolingWizard</dc:creator>
      <dc:date>2024-05-24T18:53:06Z</dc:date>
    </item>
    <item>
      <title>Re: Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622570#M120316</link>
      <description>&lt;P&gt;CoolingWizard;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Thanks for the response. I don't have a "before" picture but I can provide the diagrams showing what was connected to what.&lt;/P&gt;&lt;P&gt;The first pic is the terminal board for the XL824 thermostat:&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="XL824_Wiring.png" style="width: 383px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/52475iF03B6BB610CCAA45/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="XL824_Wiring.png" alt="XL824_Wiring.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;Rh and Rc are jumpered on the terminal block. And W2 was connected as well that's why I thought that was for the heat strips. Colored blocks are where there were connections and they are matched to this diagram below:&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="TAM7_XL824_Connections.png" style="width: 912px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/52476iCD46B67E994B8D95/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="TAM7_XL824_Connections.png" alt="TAM7_XL824_Connections.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;I'm beginning to suspect that I didn't need to connect W2 at all.&lt;/P&gt;&lt;P&gt;The BK wire is connected to the * terminal on the Nest. I wanted to setup the humidity fan function as somebody on another forum mentioned they did successfully. Not sure where in the settings that's done though.&lt;/P&gt;&lt;P&gt;Thanks again for taking a look!&lt;/P&gt;</description>
      <pubDate>Fri, 24 May 2024 20:35:13 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622570#M120316</guid>
      <dc:creator>N9</dc:creator>
      <dc:date>2024-05-24T20:35:13Z</dc:date>
    </item>
    <item>
      <title>Re: Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622702#M120351</link>
      <description>&lt;P&gt;&lt;SPAN&gt;To adjust settings like configuring the BK wire for controlling humidity fan settings, you'll likely need to navigate through the Nest menus. Look for options related to&amp;nbsp;&lt;A href="https://whatcountyamiin.org/" target="_self"&gt;your county&lt;/A&gt; humidity control or fan settings, and you should be able to configure it there.&lt;/SPAN&gt;&lt;/P&gt;</description>
      <pubDate>Sat, 25 May 2024 15:04:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/622702#M120351</guid>
      <dc:creator>williamsmithjou</dc:creator>
      <dc:date>2024-05-25T15:04:26Z</dc:date>
    </item>
    <item>
      <title>Re: Nest Gen 3 Learning on a Trane TAM7 thinks it's dual fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/623196#M120473</link>
      <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/552783"&gt;@N9&lt;/a&gt;, on the nest learning thermostat, the Star (*) Terminal&lt;/P&gt;
&lt;P&gt;&amp;nbsp;This is a Programmable functions you need to go into the settings to define what you want that to be. This can defined to be&amp;nbsp;Stage 3 heat (W3), humidification (HUM), or dehumidification (DEHUM), 3rd-speed fan relay control.&amp;nbsp;&lt;BR /&gt;&lt;BR /&gt;if my answer has helped you to understand the problem, feel free to give a kudos thumb up. If my answer helped and solved your problem, please click the recommend answer.&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;AC Cooling Wizard&lt;/P&gt;</description>
      <pubDate>Tue, 28 May 2024 15:08:00 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Nest-Gen-3-Learning-on-a-Trane-TAM7-thinks-it-s-dual-fuel/m-p/623196#M120473</guid>
      <dc:creator>CoolingWizard</dc:creator>
      <dc:date>2024-05-28T15:08:00Z</dc:date>
    </item>