<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Wiring for the Nest Learning Thermostat Dual Fuel in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624016#M120673</link>
    <description>&lt;P&gt;I have a dual fuel system. Heat Pump for heating/cooling and furnace for auxilary.&lt;/P&gt;&lt;P&gt;I've hooked up my thermostat and I've had Google support help walk me through it. Everything seems to be working properly except, I notice that the hear pump unit fan blades spin slowly continuously even though the thermostat is set to off.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;My furnace circuit board has the following wiring:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;R (red wire)&lt;/LI&gt;&lt;LI&gt;W/W1 ( white wire)&lt;/LI&gt;&lt;LI&gt;W2 ( black wire)&lt;/LI&gt;&lt;LI&gt;Y/Y2 ( orange)&lt;/LI&gt;&lt;LI&gt;G (Green)&lt;/LI&gt;&lt;LI&gt;O/B (Blue)&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;My old thermostat was wired as:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;B orientation&lt;/LI&gt;&lt;LI&gt;O/B (blue wire) to O/B&lt;/LI&gt;&lt;LI&gt;R (Red wire) to R&lt;/LI&gt;&lt;LI&gt;Y/Y2 (orange) to Y&lt;/LI&gt;&lt;LI&gt;G (Green) to G&lt;/LI&gt;&lt;LI&gt;W2 (Black wire) to W2&lt;/LI&gt;&lt;LI&gt;W/W1 (white wire) to E&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;My wiring for the nest learning:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;O/B (blue wire) to O/B&lt;/LI&gt;&lt;LI&gt;R (Red wire) to Rc&lt;/LI&gt;&lt;LI&gt;Y/Y2 (orange) to Y1&lt;/LI&gt;&lt;LI&gt;G (Green) to G&lt;/LI&gt;&lt;LI&gt;W2 (Black wire) to W2&lt;/LI&gt;&lt;LI&gt;W/W1 (white wire) to *&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;Does anyone see an issue with my wiring&lt;/P&gt;</description>
    <pubDate>Sun, 02 Jun 2024 05:41:35 GMT</pubDate>
    <dc:creator>tnikit</dc:creator>
    <dc:date>2024-06-02T05:41:35Z</dc:date>
    <item>
      <title>Wiring for the Nest Learning Thermostat Dual Fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624016#M120673</link>
      <description>&lt;P&gt;I have a dual fuel system. Heat Pump for heating/cooling and furnace for auxilary.&lt;/P&gt;&lt;P&gt;I've hooked up my thermostat and I've had Google support help walk me through it. Everything seems to be working properly except, I notice that the hear pump unit fan blades spin slowly continuously even though the thermostat is set to off.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;My furnace circuit board has the following wiring:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;R (red wire)&lt;/LI&gt;&lt;LI&gt;W/W1 ( white wire)&lt;/LI&gt;&lt;LI&gt;W2 ( black wire)&lt;/LI&gt;&lt;LI&gt;Y/Y2 ( orange)&lt;/LI&gt;&lt;LI&gt;G (Green)&lt;/LI&gt;&lt;LI&gt;O/B (Blue)&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;My old thermostat was wired as:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;B orientation&lt;/LI&gt;&lt;LI&gt;O/B (blue wire) to O/B&lt;/LI&gt;&lt;LI&gt;R (Red wire) to R&lt;/LI&gt;&lt;LI&gt;Y/Y2 (orange) to Y&lt;/LI&gt;&lt;LI&gt;G (Green) to G&lt;/LI&gt;&lt;LI&gt;W2 (Black wire) to W2&lt;/LI&gt;&lt;LI&gt;W/W1 (white wire) to E&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;My wiring for the nest learning:&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;O/B (blue wire) to O/B&lt;/LI&gt;&lt;LI&gt;R (Red wire) to Rc&lt;/LI&gt;&lt;LI&gt;Y/Y2 (orange) to Y1&lt;/LI&gt;&lt;LI&gt;G (Green) to G&lt;/LI&gt;&lt;LI&gt;W2 (Black wire) to W2&lt;/LI&gt;&lt;LI&gt;W/W1 (white wire) to *&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;Does anyone see an issue with my wiring&lt;/P&gt;</description>
      <pubDate>Sun, 02 Jun 2024 05:41:35 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624016#M120673</guid>
      <dc:creator>tnikit</dc:creator>
      <dc:date>2024-06-02T05:41:35Z</dc:date>
    </item>
    <item>
      <title>Re: Wiring for the Nest Learning Thermostat Dual Fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624637#M120852</link>
      <description>&lt;P&gt;Hi &lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/555815"&gt;@tnikit&lt;/a&gt;&lt;/SPAN&gt;,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;First I would like to thank you for posting in our community page, on the other hand I apologize for the inconvenience that you are having with your Thermostat. Let me tell you some troubleshooting steps that you can try to fix the problem.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;There might be a potential issue with your Nest Learning thermostat wiring for a dual-fuel system with a heat pump and auxiliary furnace based on the information you provided. Here's why:&lt;/SPAN&gt;&lt;/P&gt;
&lt;UL&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Missing Wire:&lt;/STRONG&gt; In your Nest wiring, the W/W1 (white wire) doesn't have a corresponding terminal mentioned. Ideally, for a dual-fuel system with a Nest Learning thermostat, the W/W1 wire (often labeled as "W1" or "Stage 1 Heat") should be connected to the&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; terminal on the Nest.&lt;/SPAN&gt;&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Here's a breakdown of the typical wiring for a dual-fuel system with a Nest Learning thermostat:&lt;/SPAN&gt;&lt;/P&gt;
&lt;UL&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;R (Red wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;Rc&lt;/STRONG&gt; on the Nest (common power)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;O/B (Blue wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;O/B&lt;/STRONG&gt; on the Nest (reversing valve)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Y/Y2 (Orange wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;Y1&lt;/STRONG&gt; on the Nest (compressor for cooling)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;G (Green wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;G&lt;/STRONG&gt; on the Nest (fan)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W2 (Black wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; on the Nest (auxiliary heat, typically furnace)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W/W1 (White wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; on the Nest (first stage heat, typically heat pump)&lt;/SPAN&gt;&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Possible Cause of Fan Running Continuously:&lt;/STRONG&gt;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;The continuously spinning fan on your heat pump even when the thermostat is set to "off" might be because the Nest doesn't detect the W1 connection (the first stage of heating, typically the heat pump). Without this connection, the Nest might be confused about the state of the heating system and keep the fan running for circulation purposes.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;If for some reason you still have the same problem don't hesitate to let us know and call our&lt;/SPAN&gt;&lt;A href="https://goo.gle/3UHTCPk" target="_blank"&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;SPAN style="background-color:#ffffff;color:#1155cc;font-size:10.5pt;"&gt;&lt;U&gt;customer service line&lt;/U&gt;&lt;/SPAN&gt;&lt;/A&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt; for further assistance&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Regards,&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Mario.&amp;nbsp;&lt;/SPAN&gt;&lt;BR /&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR /&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 06 Jun 2024 06:28:08 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624637#M120852</guid>
      <dc:creator>alejandom</dc:creator>
      <dc:date>2024-06-06T06:28:08Z</dc:date>
    </item>
    <item>
      <title>Re: Wiring for the Nest Learning Thermostat Dual Fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624899#M120895</link>
      <description>&lt;P&gt;So I tried connecting the w1 wire (used to be on E on the old thermostat) to my w1 on the nest thermostat and w2 from old to w2 on nest. But I got an error saying that there's duplicate heating issue. Also w1 wire is my furnace so technically would I need to put this to w2 on the nest, and then put the w2 wire from old thermostst to w1 on the nest?&lt;/P&gt;</description>
      <pubDate>Fri, 07 Jun 2024 13:53:03 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624899#M120895</guid>
      <dc:creator>tnikit</dc:creator>
      <dc:date>2024-06-07T13:53:03Z</dc:date>
    </item>
    <item>
      <title>Re: Wiring for the Nest Learning Thermostat Dual Fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624901#M120896</link>
      <description>&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="1000022299.jpg" style="width: 4000px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/52590i0D115D890CAD85DB/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="1000022299.jpg" alt="1000022299.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt; &lt;/P&gt;</description>
      <pubDate>Fri, 07 Jun 2024 13:54:12 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/624901#M120896</guid>
      <dc:creator>tnikit</dc:creator>
      <dc:date>2024-06-07T13:54:12Z</dc:date>
    </item>
    <item>
      <title>Re: Wiring for the Nest Learning Thermostat Dual Fuel</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/625216#M121002</link>
      <description>&lt;P&gt;Hi &lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/555815"&gt;@tnikit&lt;/a&gt;&lt;/SPAN&gt;,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;First I would like to thank you for posting in our community page, on the other hand I apologize for the inconvenience that you are having with your Thermostat and for the long wait. Let me tell you some troubleshooting steps that you can try to fix the problem.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;You're on the right track diagnosing the wiring for your Nest Learning thermostat in a dual-fuel system. Here's why you might be getting the "duplicate heating issue" and how to address it:&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Duplicate Heating Issue:&lt;/STRONG&gt;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;The error message likely pops up because the Nest detects two wires connected for first-stage heating. In your current setup:&lt;/SPAN&gt;&lt;/P&gt;
&lt;UL&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W1&lt;/STRONG&gt; (white wire) is connected to&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; on the Nest (meant for heat pump)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W2&lt;/STRONG&gt; (black wire) was previously connected to&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; on the Nest (meant for auxiliary heat, typically furnace)&lt;/SPAN&gt;&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;The Nest might be interpreting both connections as "first-stage heating," causing the error.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Correct Wiring for Dual-Fuel System:&lt;/STRONG&gt;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;For a dual-fuel system with a heat pump and auxiliary furnace, the typical wiring for the Nest Learning thermostat is:&lt;/SPAN&gt;&lt;/P&gt;
&lt;UL&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W/W1 (white wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; on the Nest (first-stage heat, typically heat pump)&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;W2 (black wire):&lt;/STRONG&gt; Connects to&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; on the Nest (auxiliary heat, typically furnace)&lt;/SPAN&gt;&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Resolving the Issue:&lt;/STRONG&gt;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Here's how you can fix the wiring and avoid the duplicate heating error:&lt;/SPAN&gt;&lt;/P&gt;
&lt;OL&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Swap W1 and W2 connections:&lt;/STRONG&gt; Move the&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; (white wire) from the&amp;nbsp;&lt;STRONG&gt;W1&lt;/STRONG&gt; terminal on the Nest to the&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; terminal.&lt;/SPAN&gt;&lt;/LI&gt;
 &lt;LI&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&lt;STRONG&gt;Leave W2 (black wire) connected:&lt;/STRONG&gt; The&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; (black wire) should already be connected to the&amp;nbsp;&lt;STRONG&gt;W2&lt;/STRONG&gt; terminal on the Nest for your auxiliary furnace.&lt;/SPAN&gt;&lt;/LI&gt;
&lt;/OL&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Regards,&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN style="background-color:#ffffff;color:#666666;font-size:10.5pt;"&gt;Mario.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR /&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;BR /&gt;&lt;BR /&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sun, 09 Jun 2024 17:35:10 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Wiring-for-the-Nest-Learning-Thermostat-Dual-Fuel/m-p/625216#M121002</guid>
      <dc:creator>alejandom</dc:creator>
      <dc:date>2024-06-09T17:35:10Z</dc:date>
    </item>
  </channel>
</rss>
