    <title>topic Re: need help wiring nest to see only my aux heating system my heat pump died in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665804#M130051</link>
    <description>&lt;P&gt;&lt;SPAN&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt; looks like you're solution works i removed and taped those wires and moved&amp;nbsp; w2 to w1&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;after I get the heatpump fixed should I keep my backup electric funrace wire in w1? I've been using the above picture setup for about year I think it makes my heatpump work overtime in the winter even after turning off heat pump balance with a lockout temp of -8c&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;what do you think about using dual fuel and w1&amp;nbsp; instead of single fuel with w2/aux with heatpump&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
    <pubDate>Sun, 29 Dec 2024 18:50:33 GMT</pubDate>
    <dc:creator>musicmike108</dc:creator>
    <dc:date>2024-12-29T18:50:33Z</dc:date>
    <item>
      <title>need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665433#M129952</link>
      <description>&lt;P&gt;Any chance someone can help with wiring my google nest to see only my electric furnance that is wired as aux&lt;/P&gt;&lt;P&gt;My heat pump died and tired of struggling to the settings to keep the thermostat to keep using aux heat&amp;nbsp;&lt;/P&gt;&lt;P&gt;I have set the heatpump lock out to the highest above 0C but would like to use only my aux electric funrance for a while until I can get the heatpump fixed&lt;/P&gt;&lt;P&gt;I know how to turn off heat pump balance but it seems the google nest gets it's charge from the Y wire and I have contstant low battery or it runs out of power at night and i have to do the settings all over again&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;looking for a way to wire the google nest to see only my electric furnace which is in the w2/aux and keep a charge&amp;nbsp;&lt;/P&gt;&lt;P&gt;as if I only have that one source of heat&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I have a heat pump (AC/Heat) and an electric funrace as secondary&amp;nbsp;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="IMG_0994.jpeg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/54423iC7436DB39D5CB235/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="IMG_0994.jpeg" alt="IMG_0994.jpeg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Fri, 27 Dec 2024 15:34:09 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665433#M129952</guid>
      <dc:creator>musicmike108</dc:creator>
      <dc:date>2024-12-27T15:34:09Z</dc:date>
    </item>
    <item>
      <title>Re: need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665687#M130001</link>
      <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/435510"&gt;@musicmike108&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;This isn't a recommended fix but it will work until you can fix the heat pump.&lt;/P&gt;
&lt;P&gt;Do this at your own risk.&lt;/P&gt;
&lt;P&gt;Remove and tape off the Y1, G, and OB wires individually.&lt;/P&gt;
&lt;P&gt;Move the W2/AUX wire to W1.&lt;/P&gt;
&lt;P&gt;You now have a heat-only system&lt;/P&gt;</description>
      <pubDate>Sun, 29 Dec 2024 01:28:10 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665687#M130001</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2024-12-29T01:28:10Z</dc:date>
    </item>
    <item>
      <title>Re: need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665777#M130036</link>
      <description>&lt;P&gt;&lt;SPAN&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt; hey thanks do you think the the nest theromstat will still charge? I was thinking what if I leave the y1 g and ob as is and move the w2 to the w1 and set the thermostat to duel fuel then set it to use alternate always?&lt;/SPAN&gt;&lt;/P&gt;</description>
      <pubDate>Sun, 29 Dec 2024 17:24:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665777#M130036</guid>
      <dc:creator>musicmike108</dc:creator>
      <dc:date>2024-12-29T17:24:26Z</dc:date>
    </item>
    <item>
      <title>Re: need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665779#M130038</link>
      <description>&lt;P&gt;&lt;SPAN&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt; seems since I had heatpump issues the thermostat battery dies I heard some systems charge by the fan wire instead of RC&lt;/SPAN&gt;&lt;/P&gt;</description>
      <pubDate>Sun, 29 Dec 2024 17:32:41 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665779#M130038</guid>
      <dc:creator>musicmike108</dc:creator>
      <dc:date>2024-12-29T17:32:41Z</dc:date>
    </item>
    <item>
      <title>Re: need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665804#M130051</link>
      <description>&lt;P&gt;&lt;SPAN&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt; looks like you're solution works i removed and taped those wires and moved&amp;nbsp; w2 to w1&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;after I get the heatpump fixed should I keep my backup electric funrace wire in w1? I've been using the above picture setup for about year I think it makes my heatpump work overtime in the winter even after turning off heat pump balance with a lockout temp of -8c&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;what do you think about using dual fuel and w1&amp;nbsp; instead of single fuel with w2/aux with heatpump&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sun, 29 Dec 2024 18:50:33 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665804#M130051</guid>
      <dc:creator>musicmike108</dc:creator>
      <dc:date>2024-12-29T18:50:33Z</dc:date>
    </item>
    <item>
      <title>Re: need help wiring nest to see only my aux heating system my heat pump died</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665824#M130054</link>
      <description>&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/435510"&gt;@musicmike108&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;You want to use the W2/AUX terminal.&lt;/P&gt;
&lt;P&gt;Dual fuel is for when you have a heat pump and a gas furnace. You have an electric furnace so single fuel is the correct choice&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sun, 29 Dec 2024 20:01:02 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/need-help-wiring-nest-to-see-only-my-aux-heating-system-my-heat-pump-died/m-p/665824#M130054</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2024-12-29T20:01:02Z</dc:date>
    </item>