<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Red wire is in C instead of R but jumper wire exist in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178167#M36266</link>
    <description>&lt;P&gt;Also hey there isnt an R area in the old circuit just an Rc and an Rh so the red wire was connected to the Rc and jumped to Rh&lt;/P&gt;</description>
    <pubDate>Thu, 09 Jun 2022 00:34:46 GMT</pubDate>
    <dc:creator>CapJoy</dc:creator>
    <dc:date>2022-06-09T00:34:46Z</dc:date>
    <item>
      <title>Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/171728#M35028</link>
      <description>&lt;P&gt;I only have 4 wire, it seems the c wire is missing (blue/black wire) I only have the green, yellow, white and red wire.&lt;/P&gt;&lt;P&gt;Whats weird to me is that the red wire is on the C terminal instead of the R terminal with a jumper cable towards the R terminal is that weird? Nest compatibility said I need a wire on R when I mentioned I only have W, Y, G, C. When I say W, Y, G, R it accepts. How would I wire this to the nest now? Do I still put the red wire to C on the nest or just leave the C empty and put it on the R terminal instead?&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;How important is the C wire in this case?&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="20220529_195418.jpg" style="width: 1068px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/9980i7E70401981C8F6CE/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="20220529_195418.jpg" alt="20220529_195418.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt; &lt;/P&gt;</description>
      <pubDate>Mon, 30 May 2022 03:59:59 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/171728#M35028</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-05-30T03:59:59Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/171755#M35045</link>
      <description>&lt;P&gt;Are you sure that it is in the C terminal? The C terminal is the return (common) for the 24VAC on the red wire.&lt;/P&gt;
&lt;P&gt;Double-check and I think you'll find the jumper is between the R and RC or RH terminals&lt;/P&gt;
&lt;P&gt;Try this wiring&lt;/P&gt;
&lt;P&gt;White - W to W&lt;/P&gt;
&lt;P&gt;Red - RC to R (jumper to R not needed)&lt;/P&gt;
&lt;P&gt;Green - G to G&lt;/P&gt;
&lt;P&gt;Yellow - Y to Y&lt;/P&gt;
&lt;P&gt;Nest thermostats are designed to work without a common ("C") wire in most homes. During installation, a small number of customers may find that the Nest Thermostat does not receive sufficient power. The&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;A class="type-cta-copy--standard" href="https://store.google.com/us/product/nest_power_connector?hl=en-US" target="_blank" rel="noopener"&gt;Nest Power Connector&lt;/A&gt;&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;or a C wire may be necessary. See&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;A class="type-cta-copy--standard" href="http://g.co/nest/cwire" target="_blank" rel="noopener"&gt;g.co/nest/cwire&lt;/A&gt;&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;for&amp;nbsp;details.&lt;/P&gt;</description>
      <pubDate>Mon, 30 May 2022 04:41:34 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/171755#M35045</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2022-05-30T04:41:34Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172427#M35187</link>
      <description>&lt;P&gt;Yes the last screw on the right which the red wire is connected to is the C terminal. R is just connected via the jumper cable.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;The terminals are in the picture top 4 from the left are W, R, B, C and bottom three is G, O, Y terminals&lt;/P&gt;&lt;P&gt;There is a jumper between the R and C terminal and the red wire is connected onto the C terminal top right last screw.&lt;/P&gt;</description>
      <pubDate>Tue, 31 May 2022 04:40:06 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172427#M35187</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-05-31T04:40:06Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172429#M35188</link>
      <description>&lt;P&gt;Actually on second thought it might be the RC terminal but then there isnt a C terminal is that normal?&lt;/P&gt;</description>
      <pubDate>Tue, 31 May 2022 04:44:06 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172429#M35188</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-05-31T04:44:06Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172436#M35190</link>
      <description>&lt;P&gt;Yes, most time a C wire wasn't needed when the thermostat had batteries or wasn't programable.&lt;/P&gt;
&lt;P&gt;You want to have a C wire installed, check for a spare wire and if one is found you can use it. I there isn't one use the Nest Power Connector&lt;/P&gt;</description>
      <pubDate>Tue, 31 May 2022 05:00:55 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/172436#M35190</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2022-05-31T05:00:55Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178120#M36262</link>
      <description>&lt;P&gt;Hey sorry, I ended up waiting for a wall plate as there were bunch of holes from previous owner.&amp;nbsp;&lt;/P&gt;&lt;P&gt;I also noticed there is a blue wire that was rolled back and unused, I'm assuming it is the C wire but how would I confirm this? Should I connect it to the nest even though the previous one wasn't?&lt;/P&gt;&lt;P&gt;Also the holes marked in blue were the old thermostat screw holes, the nest doesnt go in those so do I need to drill into new ones?&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="20220608_154300.jpg" style="width: 2309px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/10321i15EA2B937F53AA72/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="20220608_154300.jpg" alt="20220608_154300.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt; &lt;/P&gt;</description>
      <pubDate>Wed, 08 Jun 2022 22:52:08 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178120#M36262</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-06-08T22:52:08Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178167#M36266</link>
      <description>&lt;P&gt;Also hey there isnt an R area in the old circuit just an Rc and an Rh so the red wire was connected to the Rc and jumped to Rh&lt;/P&gt;</description>
      <pubDate>Thu, 09 Jun 2022 00:34:46 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178167#M36266</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-06-09T00:34:46Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178324#M36297</link>
      <description>&lt;P&gt;The best way to find out if that Blue wire is in use is to look at the terminal block on the control board in the furnace/air handler. Chances are it is not connected to anything and you can use it to make a C wire by connecting it to the C terminals on both ends.&lt;/P&gt;
&lt;P&gt;The red wire will go to the R terminal on the Nest and the jumper is not needed.&lt;/P&gt;
&lt;P&gt;Do a reset to factory defaults prior to wiring the Nest up. This will give you a clean slate to work with.&lt;/P&gt;
&lt;P&gt;Follow my earlier wiring suggestion and add in the blue wire to the C terminal.&lt;/P&gt;
&lt;P&gt;When the Google Home App ask's which wires do you have, select these.&lt;/P&gt;
&lt;P&gt;W/W1, Y/Y1, G/G1, R, and C&lt;/P&gt;</description>
      <pubDate>Thu, 09 Jun 2022 06:08:09 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/178324#M36297</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2022-06-09T06:08:09Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/180890#M36808</link>
      <description>&lt;P&gt;Hi folks,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/1389"&gt;@Patrick&lt;/a&gt;, thanks for the help!&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/163654"&gt;@CapJoy&lt;/a&gt;, how's it going? Were you able to wire your Nest Thermostat? Let us know how it goes.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks,&lt;/P&gt;
&lt;P&gt;Edward&lt;/P&gt;</description>
      <pubDate>Mon, 13 Jun 2022 18:46:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/180890#M36808</guid>
      <dc:creator>EdwardT</dc:creator>
      <dc:date>2022-06-13T18:46:26Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/181174#M36842</link>
      <description>&lt;P&gt;Hey &lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/53314"&gt;@EdwardT&lt;/a&gt;, yeah It worked out great. I didn't have chance to look at the c wire at the otherend but I did start it up without it and seems to be doing great.&amp;nbsp;&lt;/P&gt;&lt;P&gt;Bought an anchor to screw into the wall since the kit didnt come with one, its still not flush I'm thinking there is a stud behind so will need to buy a drill for it cause I cant turn the anchor in anymore with a screwdriver.&lt;/P&gt;</description>
      <pubDate>Tue, 14 Jun 2022 01:03:10 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/181174#M36842</guid>
      <dc:creator>CapJoy</dc:creator>
      <dc:date>2022-06-14T01:03:10Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/181520#M36924</link>
      <description>&lt;P&gt;Hi CapJoy,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks for the update. I'm glad to know that it's working fine. The Nest Thermostat works fine without a common wire most of the time. Please observe it for now and let us know if anything comes up.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks,&lt;/P&gt;
&lt;P&gt;Edward&lt;/P&gt;</description>
      <pubDate>Tue, 14 Jun 2022 16:18:43 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/181520#M36924</guid>
      <dc:creator>EdwardT</dc:creator>
      <dc:date>2022-06-14T16:18:43Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/184376#M37326</link>
      <description>&lt;P&gt;Hey there,&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;We haven't heard from you in a while so we'll be locking this thread if there is no update within the day. If you have any new issues, updates or just a discussion topic, feel free to start a new thread in the Community.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Best,&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Melba&lt;/P&gt;</description>
      <pubDate>Sat, 18 Jun 2022 03:19:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/184376#M37326</guid>
      <dc:creator>MelbaDT</dc:creator>
      <dc:date>2022-06-18T03:19:26Z</dc:date>
    </item>
    <item>
      <title>Re: Red wire is in C instead of R but jumper wire exist</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/185347#M37477</link>
      <description>&lt;P&gt;Hi CapJoy,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Just checking in to make sure that you've seen our response. Please let us know if you have any other questions or concerns as I will be locking this in 24 hours.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks,&lt;/P&gt;
&lt;P&gt;Edward&lt;/P&gt;</description>
      <pubDate>Sun, 19 Jun 2022 21:19:38 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Red-wire-is-in-C-instead-of-R-but-jumper-wire-exist/m-p/185347#M37477</guid>
      <dc:creator>EdwardT</dc:creator>
      <dc:date>2022-06-19T21:19:38Z</dc:date>
    </item>