<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Need Help in Replacing Honeywell ChronoTherm III T8601C with nest thermostat in Nest Thermostats</title>
    <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434885#M94178</link>
    <description>&lt;P&gt;Hi everyone,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Your thread is now identical to this primary &lt;A href="https://goo.gle/3qKUmb4" target="_blank"&gt;post&lt;/A&gt;. The main thread will be where you'll find all the updates on this matter, so we advise checking and updating it as needed.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Best,&lt;/P&gt;
&lt;P&gt;Mark&lt;/P&gt;</description>
    <pubDate>Thu, 15 Jun 2023 19:16:26 GMT</pubDate>
    <dc:creator>Markjosephp</dc:creator>
    <dc:date>2023-06-15T19:16:26Z</dc:date>
    <item>
      <title>Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432815#M93729</link>
      <description>&lt;P&gt;Sorry.&amp;nbsp; I know it is duplicate. Posting it again as I was not able to reply in my previous post under different profile.&lt;/P&gt;&lt;P&gt;In existing&amp;nbsp;Honeywell ChronoTherm III T8601C&amp;nbsp; (with wires R, G, B, W, Y ) .&amp;nbsp; White wire is connected to O terminal ,&amp;nbsp; Yellow wire is connected to W terminal. Also W and Y and connected using jumpers.&amp;nbsp; I want to replace this with Nest. Need help with wiring.&lt;/P&gt;&lt;P&gt;Update:&amp;nbsp; &amp;nbsp;I have Heat pump model&amp;nbsp; CPE30-1AB Goodman heat pump.&amp;nbsp; Very Old Model but runs geat...running for 30th year.&lt;/P&gt;&lt;P&gt;pl help with the&amp;nbsp; wiring.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Honeywell Chronotherm III T8601C.jpg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/25789i8FCAA83E02B03DFA/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Honeywell Chronotherm III T8601C.jpg" alt="Honeywell Chronotherm III T8601C.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;Nest terminals are as shown in pic&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Nest1.jpg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/25790iDAB94B5AD5E9EED6/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Nest1.jpg" alt="Nest1.jpg" /&gt;&lt;/span&gt;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 12 Jun 2023 05:18:18 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432815#M93729</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-12T05:18:18Z</dc:date>
    </item>
    <item>
      <title>Need Help in Replacing Honeywell ChronoTherm III T8601C  with nest  thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432611#M94175</link>
      <description>&lt;P&gt;In existing&amp;nbsp;Honeywell ChronoTherm III T8601C&amp;nbsp; (with wires R, G, B, W, Y ) .&amp;nbsp; White wire is connected to O terminal ,&amp;nbsp; Yellow wire is connected to W terminal. Also W and Y and connected using jumpers.&amp;nbsp; I want to replace this with Nest. Need help with wiring.&lt;/P&gt;&lt;P&gt;Update:&amp;nbsp; &amp;nbsp;I have Heat pump model&amp;nbsp; CPE30-1AB Goodman heat pump.&amp;nbsp; Very Old Model but runs gr8...running for 30th year.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Honeywell Chronotherm III T8601C.jpg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/25754iB1028561444FD039/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Honeywell Chronotherm III T8601C.jpg" alt="Honeywell Chronotherm III T8601C.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;Nest terminals are as shown in pic&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Nest thermostat terminals" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/25788i75A2765187F2DC2C/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Nest1.jpg" alt="Nest thermostat terminals" /&gt;&lt;span class="lia-inline-image-caption" onclick="event.preventDefault();"&gt;Nest thermostat terminals&lt;/span&gt;&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 12 Jun 2023 04:53:50 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432611#M94175</guid>
      <dc:creator>Shan_K</dc:creator>
      <dc:date>2023-06-12T04:53:50Z</dc:date>
    </item>
    <item>
      <title>Re: Need Help in Replacing Honeywell ChronoTherm III T8601C  with nest  thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432783#M94176</link>
      <description>&lt;P&gt;I was not able to start conversation&amp;nbsp; as reply button was disabled.&amp;nbsp; &amp;nbsp;So I am Updating&amp;nbsp; my original post by replying&amp;nbsp; to my post:&amp;nbsp; I have Heat pump model&amp;nbsp; CPE30-1AB Goodman heat pump.&amp;nbsp; Very Old Model but runs gr8...running for 30th year.&lt;/P&gt;&lt;P&gt;Nest terminals are as shown in pic&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Nest1.jpg" style="width: 999px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/25777iF79736267CCA99E0/image-size/large/is-moderation-mode/true?v=v2&amp;amp;px=999" role="button" title="Nest1.jpg" alt="Nest1.jpg" /&gt;&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 12 Jun 2023 02:42:18 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/432783#M94176</guid>
      <dc:creator>Shan_K</dc:creator>
      <dc:date>2023-06-12T02:42:18Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/433105#M93787</link>
      <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/372278"&gt;@Honeywell_sk&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Give this a try.&lt;/P&gt;
&lt;P&gt;White - O to */OB&lt;/P&gt;
&lt;P&gt;Yellow - W to Y (jumper to Y not needed)&lt;/P&gt;
&lt;P&gt;Green - G to G&lt;/P&gt;
&lt;P&gt;Blue - C to C&lt;/P&gt;
&lt;P&gt;Red - R to R&lt;/P&gt;</description>
      <pubDate>Mon, 12 Jun 2023 21:57:39 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/433105#M93787</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2023-06-12T21:57:39Z</dc:date>
    </item>
    <item>
      <title>Re: Need Help in Replacing Honeywell ChronoTherm III T8601C  with nest  thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/433115#M94177</link>
      <description>&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/372049"&gt;@Shan_K&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;See your other post for an answer.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/td-p/432815" target="_self"&gt;https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/td-p/432815&lt;/A&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 12 Jun 2023 22:12:24 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/433115#M94177</guid>
      <dc:creator>Patrick_Caezza</dc:creator>
      <dc:date>2023-06-12T22:12:24Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434187#M94039</link>
      <description>&lt;P&gt;I will try it today&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 17:41:07 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434187#M94039</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-14T17:41:07Z</dc:date>
    </item>
    <item>
      <title>Re: Need Help in Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434885#M94178</link>
      <description>&lt;P&gt;Hi everyone,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Your thread is now identical to this primary &lt;A href="https://goo.gle/3qKUmb4" target="_blank"&gt;post&lt;/A&gt;. The main thread will be where you'll find all the updates on this matter, so we advise checking and updating it as needed.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Best,&lt;/P&gt;
&lt;P&gt;Mark&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 19:16:26 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434885#M94178</guid>
      <dc:creator>Markjosephp</dc:creator>
      <dc:date>2023-06-15T19:16:26Z</dc:date>
    </item>
    <item>
      <title>Re: Need Help in Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434922#M94187</link>
      <description>&lt;P&gt;thanks&amp;nbsp;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/229711"&gt;@Markjosephp&lt;/a&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 19:54:05 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/434922#M94187</guid>
      <dc:creator>Shan_K</dc:creator>
      <dc:date>2023-06-15T19:54:05Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436062#M94381</link>
      <description>&lt;P&gt;I connected White wire to terminal O/B on Nest&lt;/P&gt;&lt;P&gt;Yellow wire to terminal Y on Nest&lt;/P&gt;&lt;P&gt;Green wire to Terminal G on nest&lt;/P&gt;&lt;P&gt;Blue wire to Terminal C on nest&amp;nbsp;&lt;/P&gt;&lt;P&gt;Red wire to Terminal R on nest ....&lt;/P&gt;&lt;P&gt;Set up Nest for cooling ... only heat come up ..indoor temp&amp;nbsp; started rising&lt;/P&gt;&lt;P&gt;So changed wire configuration&amp;nbsp; from above to&amp;nbsp; as here&amp;nbsp; -- connected White wire o Terminal W on nest&amp;nbsp; &amp;nbsp; , Connected Blue wire to Terminal C on Nest.&amp;nbsp; This too caused heat, indor temp started increasing..&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Help needed&lt;/P&gt;&lt;P&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sat, 17 Jun 2023 20:52:20 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436062#M94381</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-17T20:52:20Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436064#M94382</link>
      <description>&lt;P&gt;I connected White wire to terminal O/B on Nest&lt;/P&gt;&lt;P&gt;Yellow wire to terminal Y on Nest&lt;/P&gt;&lt;P&gt;Green wire to Terminal G on nest&lt;/P&gt;&lt;P&gt;Blue wire to Terminal C on nest&amp;nbsp;&lt;/P&gt;&lt;P&gt;Red wire to Terminal R on nest ....&lt;/P&gt;&lt;P&gt;Set up Nest for cooling ... only heat come up ..indoor temp&amp;nbsp; started rising&lt;/P&gt;&lt;P&gt;So changed wire configuration&amp;nbsp; from above to&amp;nbsp; as here&amp;nbsp; -- connected White wire o Terminal W on nest&amp;nbsp; &amp;nbsp; , Connected Blue wire to Terminal C on Nest.&amp;nbsp; This too caused heat, indor temp started increasing..&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Help needed&lt;/P&gt;</description>
      <pubDate>Sat, 17 Jun 2023 20:53:24 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436064#M94382</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-17T20:53:24Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436067#M94384</link>
      <description>&lt;P&gt;&lt;SPAN&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;connected White wire to terminal O/B on Nest&lt;/P&gt;&lt;P&gt;Yellow wire to terminal Y on Nest&lt;/P&gt;&lt;P&gt;Green wire to Terminal G on nest&lt;/P&gt;&lt;P&gt;Blue wire to Terminal C on nest&amp;nbsp;&lt;/P&gt;&lt;P&gt;Red wire to Terminal R on nest ....&lt;/P&gt;&lt;P&gt;Set up Nest for cooling ... only heat come up ..indoor temp&amp;nbsp; started rising&lt;/P&gt;&lt;P&gt;So changed wire configuration&amp;nbsp; from above to&amp;nbsp; as here&amp;nbsp; -- connected White wire o Terminal W on nest&amp;nbsp; &amp;nbsp; , Connected Blue wire to Terminal C on Nest.&amp;nbsp; This too caused heat, indor temp started increasing..&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Help needed&lt;/P&gt;</description>
      <pubDate>Sat, 17 Jun 2023 20:55:25 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436067#M94384</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-17T20:55:25Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436112#M94402</link>
      <description>&lt;P&gt;Hello there,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I wanted to stop by and see how I could help.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks for looking into this, &lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt;.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/372278"&gt;@Honeywell_sk&lt;/a&gt;, I see no wire connected specifically to the Y terminal from your old thermostat, only a jumper wire. With this, I'd suggest resetting your Nest Thermostat to its default setting and continuing the setup process. Please make sure to select the same configuration suggested above.&lt;BR /&gt;&lt;BR /&gt;Once the setup is complete, activate your system and let us know how it goes.&lt;BR /&gt;&lt;BR /&gt;Regards,&lt;BR /&gt;Mark&lt;/P&gt;</description>
      <pubDate>Sat, 17 Jun 2023 21:53:30 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436112#M94402</guid>
      <dc:creator>Markjosephp</dc:creator>
      <dc:date>2023-06-17T21:53:30Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436189#M94427</link>
      <description>&lt;P&gt;&lt;A href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54" target="_blank"&gt;@Patrick_Caezza&lt;/A&gt;&lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;Connected Y G R W ,&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;Blue wire to O/B&lt;/P&gt;&lt;P&gt;then went to Device settings Configuration in Home App&amp;nbsp; ---&amp;gt; thermostat &amp;gt; Heatpump-&amp;gt;&amp;nbsp; Highlighted Heat pump wire to O.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;This worked.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sat, 17 Jun 2023 22:57:03 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436189#M94427</guid>
      <dc:creator>Honeywell_sk</dc:creator>
      <dc:date>2023-06-17T22:57:03Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436417#M94456</link>
      <description>&lt;P&gt;&lt;A href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54" target="_blank" rel="noopener"&gt;@Patrick_Caezza&lt;/A&gt;&lt;SPAN&gt;&amp;nbsp; &amp;nbsp;&lt;/SPAN&gt;Sorry.&amp;nbsp; There was a typo in my previous answer, which has worked.&amp;nbsp; Below is correct wiring which worked&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="LivingRoom Nest thermo wiring.png" style="width: 400px;"&gt;&lt;img src="https://www.googlenestcommunity.com/t5/image/serverpage/image-id/26072iBCA707FA7FF11DB3/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="LivingRoom Nest thermo wiring.png" alt="LivingRoom Nest thermo wiring.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;then went to Device settings Configuration in Home App&amp;nbsp; ---&amp;gt; thermostat &amp;gt; Heatpump-&amp;gt;&amp;nbsp; Highlighted Heat pump wire to O.&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN&gt;This has worked. Can you think of any issue in this wiring?&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sun, 18 Jun 2023 14:15:29 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/436417#M94456</guid>
      <dc:creator>Shan_K</dc:creator>
      <dc:date>2023-06-18T14:15:29Z</dc:date>
    </item>
    <item>
      <title>Re: Replacing Honeywell ChronoTherm III T8601C with nest thermostat</title>
      <link>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/478132#M103288</link>
      <description>&lt;P&gt;Hi everyone,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I'm sorry for the delay. I know it's been a while already. Thanks for checking it with us — I'm glad that it's working. It looks like all the wires are connected to its correct terminal. Please monitor your Nest thermostat performance and efficiency. If anything comes up, let us know.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I appreciate your help, &lt;SPAN style="background: var(--ck-color-mention-background); color: var(--ck-color-mention-text);"&gt;&lt;a href="https://www.googlenestcommunity.com/t5/user/viewprofilepage/user-id/54"&gt;@Patrick_Caezza&lt;/a&gt;&lt;/SPAN&gt; and Mark.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Best,&lt;/P&gt;
&lt;P&gt;Jenelyn&lt;/P&gt;</description>
      <pubDate>Thu, 07 Sep 2023 15:51:39 GMT</pubDate>
      <guid>https://www.googlenestcommunity.com/t5/Nest-Thermostats/Replacing-Honeywell-ChronoTherm-III-T8601C-with-nest-thermostat/m-p/478132#M103288</guid>
      <dc:creator>Jenelyn_O</dc:creator>
      <dc:date>2023-09-07T15:51:39Z</dc:date>
    </item>