04-06-2022 10:38 AM
I have modelg4cvz
below is what have
04-06-2022 01:32 PM
Tape off the brown E/W1 wire and any will work. If you want separate emergency heat control then you need the 3rd Gen Learning version.
04-06-2022 05:56 PM
Your system is only compatible with the Nest 3rd Gen Learning Thermostat.
You can wire it like this
Red - R to Rc
Orange - O to OB
Black - C to C
Yellow - Y1 yo Y1
Brown - E/W1 to * (set as Emergency Heat)
Green - G to G
White - W2 to W2
04-13-2022 12:01 AM
Hey folks,
Thanks for the detailed answer and suggestions, Patrick_Caezza and Stuff.
erikking18, I'm chiming in to check if everything is covered here. Let us know if you still have questions.
Best,
Melba
04-16-2022 12:07 AM
Hey erikking18,
Checking back in — how's your thermostat now?
Best,
Melba
04-18-2022 11:51 PM
Hi,
I haven't heard from you in a while so I'll be locking this thread if there is no update within the day. If you have any new issues, updates or just a discussion topic, feel free to start a new thread in the community.
Best,
Melba